Tankless Flow Calculator

A tankless heater makes hot water as you use it, so its size comes down to flow and temperature rise. Choose the showers and fixtures that run at the same time to see what a unit has to deliver.

Pick your place and we set the incoming water temperature from its winter weather.

Showers running at once
At the same time as the showers

What runs at the same time

A tank stores hot water. A tankless unit makes it as you go, so it is sized in gallons per minute, not gallons. Add up what realistically runs together. We use 2.5 gallons per minute for a showerhead, which is the federal limit, about 1.8 for a faucet and about 2 for a dishwasher or washer. Two showers at once already means 5.

How cold the water comes in

The tool sets a 120°F target and estimates the incoming temperature from the average January low. That gives 42°F water below 25°F, 52°F water from 25°F to 39°F and 65°F water at 40°F or above. Richardson’s 35°F January low is in the middle band, so the unit has to add 68°F.

How the size is worked out

The heat a unit has to deliver each hour is the flow in gallons per minute, times the rise in degrees, times 500. That figure comes from the weight of a gallon of water. We round it and place it in one of our own planning bands, based on that delivered heat. Up to 90,000 BTU per hour is a small unit. Up to 150,000 is a standard whole-house unit. Up to 190,000 is a large unit. Above that, two units are linked together.

A tankless unit trades flow for rise. The same unit gives more gallons per minute at a small rise than at a big one, which is why every tankless rating is stated at a rise.

Gas and electric limits

Gas units go up to about 199,000 BTU per hour of input, and two can be linked. Electric units top out near 36 kW, about 123,000 BTU per hour, and they need a very large electrical service. The result shows how many gallons per minute each one delivers at your rise. A plumber or an electrician checks the gas line, the electrical service and the venting before any unit is chosen.

Common questions

Which tankless size suits a family of four?

The answer depends on showers running at the same time, and two draw 5 gallons per minute. At Richardson’s 68°F rise that flow needs about 170,000 BTU per hour, which the calculator puts in its large-unit class. A dishwasher or another faucet running as well calls for two units linked together.

Do two showers at once work on one tankless unit?

They do on a large gas unit, which delivers about 5.6 gallons per minute when the water rises 68°F, as Richardson’s does. Two showers need 5. An electric unit manages roughly 3.6 gallons per minute and falls short.

Does colder supply water change what a tankless unit puts out?

Yes. Rise means the degrees a unit adds from incoming to outgoing water. Richardson’s is figured at 52°F in and 120°F out, which is 68°F, and delivery in gallons per minute drops as the rise grows.

Will an electric tankless unit heat a whole house?

Not with two showers running together. Even the largest electric models, around 36 kW, give roughly 3.6 gallons per minute at a 68°F rise, which is one shower. An electrician also has to confirm the home’s electrical service can carry the load.

Does a tankless water heater need a bigger gas line?

Often. A 199,000 BTU per hour unit draws several times what a tank heater does, and the existing gas line and venting may not be sized for it. A plumber checks both first.

Data: fixture flow rates from the federal showerhead limit and typical faucet and appliance flows, the 120°F setpoint recommended by the US Department of Energy, and incoming water bands set from Daymet winter data 2015 to 2024 for each place.